Massive parallel sequencingMassive parallel sequencing or massively parallel sequencing is any of several high-throughput approaches to DNA sequencing using the concept of massively parallel processing; it is also called next-generation sequencing (NGS) or second-generation sequencing. Some of these technologies emerged between 1993 and 1998 and have been commercially available since 2005. These technologies use miniaturized and parallelized platforms for sequencing of 1 million to 43 billion short reads (50 to 400 bases each) per instrument run.
Séquençage de l'ADNcadre|Résultat du séquençage par la méthode de Sanger. L'ordre de chaque bande indique la position d'un nucléotide A,T,C ou G Le séquençage de l'ADN consiste à déterminer l'ordre d'enchaînement des nucléotides pour un fragment d’ADN donné. La séquence d’ADN contient l’information nécessaire aux êtres vivants pour survivre et se reproduire. Déterminer cette séquence est donc utile aussi bien pour les recherches visant à savoir comment vivent les organismes que pour des sujets appliqués.
SéquençageEn biochimie, le séquençage consiste à déterminer l'ordre linéaire des composants d'une macromolécule (les acides aminés d'une protéine, les nucléotides d'un acide nucléique comme l'ADN, les monosaccharides d'un polysaccharide, etc.). En génétique, le séquençage concerne la détermination de la séquence des gènes voire des chromosomes, voire du génome complet, ce qui techniquement revient à effectuer le séquençage de l'ADN constituant ces gènes ou ces chromosomes.
Sanger sequencingSanger sequencing is a method of DNA sequencing that involves electrophoresis and is based on the random incorporation of chain-terminating dideoxynucleotides by DNA polymerase during in vitro DNA replication. After first being developed by Frederick Sanger and colleagues in 1977, it became the most widely used sequencing method for approximately 40 years. It was first commercialized by Applied Biosystems in 1986. More recently, higher volume Sanger sequencing has been replaced by next generation sequencing methods, especially for large-scale, automated genome analyses.
Séquençage shotgunEn génétique, le séquençage shotgun (littéralement séquençage "fusil de chasse") est une méthode utilisée pour séquencer des brins d'ADN aléatoires. On l'appelle ainsi par analogie avec le modèle de tir quasi-aléatoire en pleine expansion d'un fusil de chasse : cette métaphore illustre le caractère aléatoire de la fragmentation initiale de l'ADN génomique où l'on "arrose" tout le génome, un peu comme se dispersent les plombs de ce type d'arme à feu.
PyroséquençageLe pyroséquençage est une technique de séquençage de l'ADN qui permet d’effectuer un séquençage rapide et à moindre coût qu’un séquençage par la méthode de Sanger. En effet, cette technique ne nécessite pas de clonage (donc gain de temps et d’argent), et permet une lecture directe de la séquence obtenue après le séquençage. Elle est basée sur le principe du « séquençage par synthèse », dans lequel le séquençage est effectué en détectant le nucléotide incorporé par une ADN polymérase.
Sonde fluorescentevignette|Utilisation de sondes fluorescentes pour être capable de visualiser des structures qui sont, en temps normal, invisibles de par leur taille. Cellules endothéliales vues au microscope. En bleu, noyaux marqués au DAPI. En vert, microtubules marqués par un anticorps couplé à un fluorochrome. En rouge, actine marquée à la phalloïdine. Une sonde fluorescente est une molécule fluorescente que l'on ajoute à un milieu (cellule ou monocouche, par exemple) pour mettre en évidence certaines zones et/ou pour étudier les propriétés physiques d'un milieu.
FluorochromeUn fluorochrome ou fluorophore est une substance chimique capable d'émettre de la lumière de fluorescence après excitation. Ce sont des substances composées de plusieurs noyaux aromatiques conjugués ou encore des molécules planes et cycliques qui possèdent une ou plusieurs liaisons π. L'utilisation de fluorochromes en biologie moléculaire est un peu plus récente que celle d'isotopes radioactifs. Elle a l'avantage de donner des résultats très rapidement, voire immédiatement, en s'affranchissant des longs temps d'exposition requis pour la technique par radioactivité.
Third-generation sequencingThird-generation sequencing (also known as long-read sequencing) is a class of DNA sequencing methods currently under active development. Third generation sequencing technologies have the capability to produce substantially longer reads than second generation sequencing, also known as next-generation sequencing. Such an advantage has critical implications for both genome science and the study of biology in general. However, third generation sequencing data have much higher error rates than previous technologies, which can complicate downstream genome assembly and analysis of the resulting data.
Protéine fluorescente vertevignette|Aequorea victoria. La protéine fluorescente verte (souvent abrégé GFP, de l'anglais « Green Fluorescent Protein ») est une protéine ayant la propriété d'émettre une fluorescence de couleur verte. Issue d'une méduse (Aequorea victoria), cette protéine est intrinsèquement fluorescente sous l'action d'une enzyme, l'aequoréine, une luciférase qui agit en présence de calcium. Son gène peut être fusionné in-vitro au gène d'une protéine que l'on souhaite étudier.
Bisulfite sequencingBisulfite sequencing (also known as bisulphite sequencing) is the use of bisulfite treatment of DNA before routine sequencing to determine the pattern of methylation. DNA methylation was the first discovered epigenetic mark, and remains the most studied. In animals it predominantly involves the addition of a methyl group to the carbon-5 position of cytosine residues of the dinucleotide CpG, and is implicated in repression of transcriptional activity.
Whole genome sequencingWhole genome sequencing (WGS), also known as full genome sequencing, complete genome sequencing, or entire genome sequencing, is the process of determining the entirety, or nearly the entirety, of the DNA sequence of an organism's genome at a single time. This entails sequencing all of an organism's chromosomal DNA as well as DNA contained in the mitochondria and, for plants, in the chloroplast. Whole genome sequencing has largely been used as a research tool, but was being introduced to clinics in 2014.
Exome sequencingExome sequencing, also known as whole exome sequencing (WES), is a genomic technique for sequencing all of the protein-coding regions of genes in a genome (known as the exome). It consists of two steps: the first step is to select only the subset of DNA that encodes proteins. These regions are known as exons—humans have about 180,000 exons, constituting about 1% of the human genome, or approximately 30 million base pairs. The second step is to sequence the exonic DNA using any high-throughput DNA sequencing technology.
Projet Génome humainvignette|Le génome humain est constitué de l'ensemble de l'information portée par nos 23 paires de chromosomes. Le (PGH, ou HGP pour l'anglais Human Genome Project) est un programme lancé fin 1988 dont la mission était d'établir le séquençage complet de l'ADN du génome humain. Son achèvement a été annoncé le . Le nouveau projet lancé dans la foulée en , ENCODE (Encyclopedia of DNA Elements), donne des résultats importants sur l'ADN non codant humain.
LuciférineLes luciférines sont des molécules dont l'oxydation, sous le contrôle d'une enzyme, la luciférase, aboutit à la formation d'oxyluciférine et à l'émission de photons. La luciférine a été découverte chez plus de 300 espèces capables de bioluminescence. Il existe cinq types de luciférine, chacun étant lié à une luciférase spécifique. Luciférine de luciole L'espèce la plus étudiée est Photinus pyralis (le lampyre), dont la réaction de bioluminescence nécessite la présence d'ATP et de magnésium.
Bioluminescencevignette|Rendu artistique d'un krill bioluminescent (aquarelle d'Uwe Kils). vignette|Bioluminescence du champignon Panellus stipticus. vignette|Vue rapprochée d'un coléoptère bioluminescent Elateroidea. vignette|Panellus stipticus. La bioluminescence est la production et l'émission de lumière par un organisme vivant via une réaction chimique au cours de laquelle l'énergie chimique est convertie en énergie lumineuse. Le mot a pour origine le terme grec bios signifiant vie et le terme latin lumen, lumière.
LuciféraseLes luciférases sont les enzymes clés de la réaction de bioluminescence. La luciférase la plus connue est celle de Photinus pyralis, soit une luciole de la famille des Lampyridae. Cette enzyme est classée comme une mono-oxygénase ATP-dépendante. C’est une enzyme bifonctionnelle puisqu’elle catalyse les réactions de deux voies métaboliques distinctes, soit la voie de bioluminescence et la voie de synthèse de l’acyl-CoA. Le terme Luciférase est dû à Raphaël Dubois, pionnier de l'étude des principes chimiques de la bioluminescence.
Réaction en chaîne par polymérasevignette|Diagramme des quatre premiers cycles de la PCR. Lamplification en chaîne par polymérase (ACP) ou réaction de polymérisation en chaîne, généralement siglée PCR (de l'polymerase chain reaction) est une méthode de biologie moléculaire permettant d'obtenir rapidement, in vitro, un grand nombre de segments d'ADN identiques, à partir d'une séquence initiale.
FluorescenceLa fluorescence est une émission lumineuse provoquée par l'excitation des électrons d'une molécule (ou atome), généralement par absorption d'un photon immédiatement suivie d'une émission spontanée. Fluorescence et phosphorescence sont deux formes différentes de luminescence qui diffèrent notamment par la durée de l'émission après excitation : la fluorescence cesse très rapidement tandis que la phosphorescence perdure plus longtemps. La fluorescence peut entre autres servir à caractériser un matériau.
Chimiluminescencethumb|Une réaction chimioluminescente. La chimiluminescence, ou chimioluminescence, est la production de lumière à la suite d'une réaction chimique. Une réaction de ce type est l'oxydo-réduction du luminol (3-aminophthalhydrazide) par l'eau oxygénée (), par exemple, ou un quelconque oxydant. Durant une réaction de chimiluminescence, une molécule de type diester ou amide entre dans un état excité et transfère cette énergie à un accepteur (porteur de luminescence).