Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Systematic errors due to the neglect of water and/or ethanol partition between liq. and gaseous phases are discussed for bioreactors equipped with or without a condenser. Both water vapor and ethanol vapor are present in the off-gas leaving the condenser. Presence of residual water vapor largely influences the gas measurements by diln. As a consequence, the oxygen consumption rate can be overestimated by a factor of 3 if calcns. are not cor. for water vapor content or if no addnl. device is implemented.after the condenser to completely dry the off-gases. The mass balance and partition equations predict that the condenser has only a small effect on redn. of the ethanol vapor content of the off-gas. The reason is the high ethanol concn. of the condensate droplets on the condenser wall in contact with the off-gases. Model predictions as well as exptl. results show that ethanol evapn. represents a large fraction of the ethanol prodn. rate and influences greatly the elemental recoveries. For a reactor working at 30 DegC without condensation of the vapors and for a volumetric aeration rate of 0.63vvm, stripping of ethanol resulted in a gaseous diln. rate of 0.016 h-1 for ethanol. The diln. rate by stripping was reduced to 0.014 h-1 when a condenser at 12 DegC was implemented. The fraction of ethanol that is stripped is mainly dependent on the ratio D/vvm (liq. to gaseous flow rates), and the effect is only slightly influenced by low condenser temp. The evapn. of ethanol may account for more than 20% of the ethanol formation rate. Therefore, the condenser does not succeed to reflux all ethanol to the reactor broth. In terms of a unit operation, ethanol vapor can be efficiently reduced by absorption instead of condensation. To demonstrate the feasibility, a simple modification of the reactor was tested for continuous cultures: the feed port was changed from the top-plate to the top of the condenser, which was used as an absorption column. Ethanol stripping was reduced by a factor of 4 as compared to the condensation setup (at 12 DegC): it accounted for 2% of the ethanol prodn. rate as compared to 8.2% at D = 0.19 h-1 and 0.63vvm. [on SciFinder (R)]
Florian Frédéric Vincent Breider