DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
In the framework of the conductor optimisation task (CONDOPT) five NbTi subsize cable-in-conduit conductors with parametric variations were fabricated. The DC performance of these conductors tested in the SULTAN test facility [IEEE Trans. Appl. Supercond. 12 (2002) 520] and the strand properties including the voltage-current characteristic, are compared. The results clearly indicate that the current carrying capacity of the conductors is considerably reduced due to the self-field. In conductors with a hindered interstrand current sharing, the critical current has been found to be even below the predicted value at the peak field, suggesting an uneven current distribution among the strands. (C) 2003 Elsevier B.V. All rights reserved.
Yves Perriard, Christian Köchli