DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A novel configuration of a distributed fiber sensor by Brillouin gain analysis has been developed for temperature and strain monitoring. It uses a single laser source, and the required light signals are all generated with an electro-optic modulator, resulting in high stability and excellent reliability of the measuring setup. Measurement of the induced strain in a wound fiber is presented as a demonstration of the system performance
Thomas Sidler, Sébastian Favre
Hans Georg Limberger, René Dändliker