Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
In modern power systems, Rate of Change of Frequency (ROCOF) is employed in monitoring and control applications. However, a standard approach towards ROCOF measurements is still missing. In this paper, we investigate the feasibility of Phasor Measurement Units (PMUs) deployment in ROCOF -based applications. For this analysis, we select three representative synchrophasor estimation algorithms and compare their accuracy in datasets inspired by real-world acquisitions. Based on the proposed results, PMUs prove to be accurate ROCOF meters, as long as the harmonic and inter-harmonic distortion within the measurement pass-band is reduced. In the presence of transient events, the synchrophasor model looses its appropriateness, as the signal energy spreads over the entire spectrum and cannot be approximated as a sequence of narrowband components. For these reasons, a re-definition of the IEEE Std. C37.118.1 requirements is recommended to suitably define ROCOF measurements based on real-world operating conditions.