DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Two subsize, Nb3Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I, and n-factor is observed upon cyclic load, with a drop of the critical current, I-c, larger than 30%. The results are critically discussed and compared to similar findings from the literature. The impact of the cyclic load on the Nb3Sn CICC performance must be carefully evaluated in the magnet design.