DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A new fully integrated 2D micro-fluxgate magnetometer is presented. This magnetometer is integrated in a standard CMOS process and uses a ferromagnetic core integrated on the chip by a photolithographic post process compatible to the integrated circuit technology. This core is placed diagonally above four excitation coils, two for each measurement axis. A novel electronic signal extraction technique is presented, whose realization results in a magnetic sensitivity of 160 V/T and a linear range of ± 50 μT. The magnetic equivalent noise spectral density is 70 nT/√Hz at 1 Hz, and the total power consumption is as low as 25 mW for the 5 V power supply.