Bright-field microscopyBright-field microscopy (BF) is the simplest of all the optical microscopy illumination techniques. Sample illumination is transmitted (i.e., illuminated from below and observed from above) white light, and contrast in the sample is caused by attenuation of the transmitted light in dense areas of the sample. Bright-field microscopy is the simplest of a range of techniques used for illumination of samples in light microscopes, and its simplicity makes it a popular technique.
Cross slipIn materials science, cross slip is the process by which a screw dislocation moves from one slip plane to another due to local stresses. It allows non-planar movement of screw dislocations. Non-planar movement of edge dislocations is achieved through climb. Since the Burgers vector of a perfect screw dislocation is parallel to the dislocation line, it has an infinite number of possible slip planes (planes containing the dislocation line and the Burgers vector), unlike an edge or mixed dislocation, which has a unique slip plane.
Microsonde de CastaingLa microsonde de Castaing (en anglais electron probe microanalyser, EPMA) est une méthode d'analyse élémentaire inventée en 1951 par Raimond Castaing. Elle consiste à bombarder un échantillon avec des électrons et à analyser le spectre des rayons X émis par l'échantillon sous cette sollicitation. Lors du bombardement d'un échantillon, certains électrons cèdent une partie de leur énergie cinétique à l'atome, provoquant l'éjection d'un électron de l'atome ; l'atome est dit « excité ».
Spectrométrie photoélectronique Xvignette|upright=1.4|Machine XPS avec un analyseur de masse (A), des lentilles électromagnétiques (B), une chambre d'ultra-vide (C), une source de rayon X (D) et une pompe à vide (E) La spectrométrie photoélectronique X, ou spectrométrie de photoélectrons induits par rayons X (en anglais, X-Ray photoelectron spectrometry : XPS) est une méthode de spectrométrie photoélectronique qui implique la mesure des spectres de photoélectrons induits par des photons de rayon X.
Phase-contrast X-ray imagingPhase-contrast X-ray imaging or phase-sensitive X-ray imaging is a general term for different technical methods that use information concerning changes in the phase of an X-ray beam that passes through an object in order to create its images. Standard X-ray imaging techniques like radiography or computed tomography (CT) rely on a decrease of the X-ray beam's intensity (attenuation) when traversing the sample, which can be measured directly with the assistance of an X-ray detector.
Lampe à incandescencevignette|upright=0.75|Lampe à incandescence classique Une lampe à incandescence, ou ampoule à incandescence par métonymie, est un luminaire électrique qui éclaire en portant à incandescence par effet Joule un filament de tungstène, le métal qui a le plus haut point de fusion (). Expérimentée au milieu du , la lampe à incandescence, perfectionnée au cours du , est devenue au cours de ce siècle la principale source d'éclairage. Au , sa mauvaise efficacité lumineuse fait préconiser officiellement d'autres procédés.
Diode laserUne diode laser est un composant opto-électronique à base de matériaux semi-conducteurs. Elle émet de la lumière monochromatique cohérente (une puissance optique) destinée, entre autres, à transporter un signal contenant des informations sur de longues distances (dans le cas d'un système de télécommunications) ou à apporter de l'énergie lumineuse pour le pompage de certains lasers (lasers à fibre, laser DPSS) et amplificateurs optiques (OFA, Optical Fiber Amplifier).
Spectrométrie de fluorescence des rayons Xthumb|Analyseur portatif (Olympus Delta Professional XRF donnant la quantité de contaminants métalliques ou métalloïdes dans le sol. contaminants préoccupants recherchés sont ici le plomb, le mercure, le cadmium et l'arsenic. La spectrométrie de fluorescence des rayons X (SFX ou FX, ou en anglais XRF pour X-ray fluorescence) est une technique d'analyse chimique utilisant une propriété physique de la matière, la fluorescence de rayons X.