Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
To evaluate the differences between non-circular shape of FloWatch®-PAB and conventional pulmonary artery (PA) banding. Methods: Geometrical analysis. Conventional banding and FloWatch®-PAB perimeters were plotted against cross-sections. Computational fluid dynamics (CFD) model. CFD compared non-circular FloWatch®-PAB cross-sections with conventional banding regarding pressure gradients. Clinical data. Seven children, median age 2 months (7 days to 3 years), median weight 4.2 kg (3.2–9.8 kg), with complex congenital heart defects underwent PA banding with FloWatch®-PAB implantation. Results: Geometrical analysis. Conventional banding: progressive reduction of cross-sections was accompanied by progressive reduction of PA perimeters. FloWatch®-PAB: with equal reduction of cross-sections the PA perimeter remained constant. CFD model. Non-circular and circular banding provided same trans-banding pressure gradients for same cross-sections at any given flow. Clinical data. Mean PA internal diameter at banding was 13.3 ± 4.5 mm. After a mean interval of 5.9 ± 3.7 months, all children underwent intra-cardiac repair and simple FloWatch®-PAB removal without PA reconstruction. Mean PA internal diameter with FloWatch®-PAB removal increased from 3.0 ± 0.8 to 12.4 ± 4.5 mm (normal mean internal diameter for the age = 9.9 ± 1.6). No residual pressure gradient was recorded in correspondence of the site of the previous FloWatch®-PAB implantation in 6/7 patients, 10 mmHg peak and 5 mmHg mean gradient in 1/7. Conclusions: The non-circular shape of FloWatch®-PAB can replace conventional circular banding with the following advantages: (a) the pressure gradient will remain essentially the same as for conventional circular banding for any given cross-section, but with significantly smaller reduction of PA perimeter; and (b) PA reconstruction at the time of de-banding for intra-cardiac repair can be avoided.
Nikolaos Stergiopoulos, Vasiliki Bikia, Georgios Rovas, Sokratis Anagnostopoulos