Cellule galvaniqueA galvanic cell or voltaic cell, named after the scientists Luigi Galvani and Alessandro Volta, respectively, is an electrochemical cell in which an electric current is generated from spontaneous Oxidation-Reduction reactions. A common apparatus generally consists of two different metals, each immersed in separate beakers containing their respective metal ions in solution that are connected by a salt bridge or separated by a porous membrane. Volta was the inventor of the voltaic pile, the first electrical battery.
Electrolytic cellAn electrolytic cell is an electrochemical cell that utilizes an external source of electrical energy to force a chemical reaction that would otherwise not occur. The external energy source is a voltage applied between the cell′s two electrodes; an anode (positively charged electrode) and a cathode (negatively charged electrode), which are immersed in an electrolyte solution. This is in contrast to a galvanic cell, which itself is a source of electrical energy and the foundation of a battery.
Équation de NernstEn électrochimie, l'équation de Nernst donne la tension d'équilibre (E) de l'électrode par rapport au potentiel standard (E) du couple redox mis en jeu. Elle n'a de sens que si un seul couple redox est présent en solution (l'équation de Nernst ne s'applique donc pas aux potentiels mixtes) et que si les deux espèces de ce couple sont présentes. Soit la demi-réaction redox suivante toujours présentée dans le sens de la réduction.
ÉlectrodeUne électrode est un conducteur électronique, ou ionique ( verre) captant ou libérant des électrons. Les électrodes interviennent dans les systèmes générateurs de courant (comme les piles ou les accumulateurs électriques) et dans les électrolyses, dont le système est récepteur de courant. On parle aussi d'électrodes pour désigner des composants de certains appareils électriques comme les lampes radio, tube à rayons X, diodes à semi-conducteur. C'est également le cas dans le soudage à l'arc électrique.
Surface chargeA surface charge is an electric charge present on a two-dimensional surface. These electric charges are constrained on this 2-D surface, and surface charge density, measured in coulombs per square meter (C•m−2), is used to describe the charge distribution on the surface. The electric potential is continuous across a surface charge and the electric field is discontinuous, but not infinite; this is unless the surface charge consists of a dipole layer. In comparison, the potential and electric field both diverge at any point charge or linear charge.
Réaction chimiqueUne réaction chimique est une transformation de la matière au cours de laquelle les espèces chimiques qui constituent la matière sont modifiées. Les espèces qui sont consommées sont appelées réactifs ; les espèces formées au cours de la réaction sont appelées produits. Depuis les travaux de Lavoisier (1777), les scientifiques savent que la réaction chimique se fait sans variation mesurable de la masse : , qui traduit la conservation de la masse. thumb|La réaction aluminothermique est une oxydo-réduction spectaculaire.
Proton-transfer-reaction mass spectrometryProton-transfer-reaction mass spectrometry (PTR-MS) is an analytical chemistry technique that uses gas phase hydronium reagent ions which are produced in an ion source. PTR-MS is used for online monitoring of volatile organic compounds (VOCs) in ambient air and was developed in 1995 by scientists at the Institut für Ionenphysik at the Leopold-Franzens University in Innsbruck, Austria. A PTR-MS instrument consists of an ion source that is directly connected to a drift tube (in contrast to SIFT-MS no mass filter is interconnected) and an analyzing system (quadrupole mass analyzer or time-of-flight mass spectrometer).
ÉlectrolyteUn électrolyte est une substance conductrice en raison de la présence d'ions mobiles. Il existe des électrolytes liquides et solides. Les électrolytes liquides peuvent être des sels fondus, constitués uniquement d'ions, ou des solutions ioniques dans lesquelles un sel est dissous dans un solvant polaire comme l'eau. Les électrolytes solides sont des cristaux dans lesquels certains ions sont mobiles ou des polymères comme ceux utilisés dans les membranes échangeuses d'ions.
Réaction péricycliqueEn chimie organique, une réaction péricyclique est une réaction dans laquelle une réorganisation concertée des liaisons passe par un ensemble cyclique d'atomes (comprenant souvent six atomes) liés en permanence. L'état de transition possède une géométrie cyclique. Les réactions péricycliques sont généralement des réactions de réarrangement. On distingue : les cycloadditions ; les réactions chélotropes ; les réactions électrocycliques ; les transpositions sigmatropiques ; les réactions de transfert de groupe ; les réactions dyotropiques.
Électrocatalyseurthumb|Mesure de la stabilité d'un électrocatalyseur à cathode en platine. Un électrocatalyseur est un catalyseur de réactions électrochimiques. Un électrocatalyseur facilite le transfert d'électrons entre la surface de l'électrode et les réactifs. Dans certains cas, un électrocatalyseur facilite une transformation chimique intermédiaire qui est décrite par une demi-réaction globale. Un électrocatalyseur peut être hétérogène (exemple : une surface de platine ou des nanoparticules), ou homogène (exemple : un complexe de coordination ou une enzyme).
Double couche électriqueLa double couche électrique est un modèle décrivant la variation du potentiel électrique aux abords d'une surface. Elle intervient principalement lors de l'étude du comportement des colloïdes et des surfaces en contact avec des solutions. L'épaisseur de la double couche électrique est appelée longueur de Debye. Le modèle initial de la double couche électrique est attribué à Helmholtz (1879). Mathématiquement, il a simplement assimilé la double couche à un condensateur, en se basant sur un modèle physique dans lequel une couche d'ions est adsorbée à la surface.
Ene reactionIn organic chemistry, the ene reaction (also known as the Alder-ene reaction by its discoverer Kurt Alder in 1943) is a chemical reaction between an alkene with an allylic hydrogen (the ene) and a compound containing a multiple bond (the enophile), in order to form a new σ-bond with migration of the ene double bond and 1,5 hydrogen shift. The product is a substituted alkene with the double bond shifted to the allylic position. This transformation is a group transfer pericyclic reaction, and therefore, usually requires highly activated substrates and/or high temperatures.
Réaction endergoniquevignette|Graphe de l'évolution de l'énergie par le temps dans une réaction endergonique. Une réaction endergonique est une réaction chimique nécessitant un apport d'énergie. C'est une réaction pour laquelle la variation de l'enthalpie libre (, fonction de Gibbs) est positive. Les variations de l'énergie libre incluent les variations de l'enthalpie et de l'entropie, à la différence des réactions exothermiques et endothermiques, qui ne se définissent que par des variations de l'enthalpie seule, ces dernières étant liées à une perte ou un gain de chaleur.
Liquidevignette|L'eau est une substance abondante sur la surface terrestre, se manifestant notamment sous forme de liquide. vignette|Diagramme montrant comment sont configurés les molécules et les atomes pour les différents états de la matière.
Charge électriqueLa charge électrique est une propriété fondamentale de la matière qui lui permet d'interagir par le biais de champs électromagnétiques. Il s'agit d'une grandeur scalaire, qui joue pour l'interaction électromagnétique le même rôle que la masse pour l'interaction gravitationnelle. Toutefois, contrairement à cette dernière, il existe deux types de charges électriques que l'on distingue par leurs signes positif ou négatif. Des charges de même signe se repoussent, tandis que celles de signes opposés s'attirent.
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Réaction d'éliminationEn chimie organique, une élimination (ou β-élimination) est une réaction organique qui transforme un alcane substitué (halogénoalcanes, alcools...) en dérivé éthylénique, voire en alcène, si la molécule de départ, outre le groupe partant, n'est qu'une chaîne carbonée de type alcane. Les conditions sont, en plus dures, celles d'une substitution nucléophile, réaction proche par de nombreux aspects et concurrente : l'élimination se produit en présence d'une base forte et en chauffant le mélange réactionnel.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Réaction réversibleUne réaction réversible est une réaction dans laquelle se produisent simultanément la conversion des réactifs en produits et la conversion des produits en réactifs. aA + bB cC + dD A et B peuvent réagir pour former C et D, ou C et D peuvent réagir pour former A et B dans la réaction inverse. Ceci est distinct d'un processus réversible en thermodynamique. Les acides et les bases faibles subissent des réactions réversibles. Par exemple, l'acide carbonique : H 2 CO 3 (l) + H 2 O (l) ⇌ HCO 3 − (aq) + H 3 O + (aq) .
Pont salinUn pont salin ou pont électrolytique, en électrochimie, est un petit équipement de laboratoire utilisé pour connecter deux compartiments d'une cellule galvanique, un type de cellule électrochimique. Chacun des compartiments contient une solution contenant l'oxydant et le réducteur d'un couple redox (chaque compartiment est une demi-cellule). Le pont salin contient un électrolyte inerte du point de vue électrochimique et permet donc la conduction d'un courant électrique entre les deux demi-cellules sans que les deux solutions se mélangent.