Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
An accurate epileptic seizure detector using intracranial electroencephalography (iEEG) recordings, suitable for low-power wearable/implantable applications, is presented. Eleven time-domain features with low hardware complexity are employed in the feature pool of the seizure detector. A novel two-step feature ranking algorithm based on maximum discrimination minimum redundancy (MDMR) is proposed to identify the most discriminating features in a patient-specific manner during a training phase. Subsequently, the top-ranked features are extracted in a two-stage energy-efficient architecture in which the second stage is activated by a controller to avoid unnecessary energy consumption imposed by multiple feature extraction during the long period of non-seizure states. The effective number of features which are continuously extracted is reduced in this work. Moreover, a patient-specific data reduction technique which selects the most informative and discriminating iEEG channels is also proposed. The presented channel selection technique reaches 68% data reduction on average for the tested patients and reduces the computational complexity. The proposed algorithm is implemented on Cyclone V FPGA of Terasic DE10-standard board. It is tested on twelve patients with short-term and long-term seizures from the Bern Inselspital dataset. The FPGA implementation results reveal an excellent sensitivity of 100% for all patients and remarkable specificity and detection delay improvement compared to the state-of-the-art. The average dynamic power consumption is 0.49 mW which is in the acceptable range for low-power wearable/implantable applications. In addition, a new figure-of-merit (FoM_SD) is defined to consider the major parameters of the seizure detectors. The outstanding FoM_SD of this work is 0.464 which outperforms the state-of-the-art.
David Atienza Alonso, Giovanni Ansaloni, Flavio Ponzina, José Angel Miranda Calero, Jonathan Dan, Amirhossein Shahbazinia