Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
A summary of the objectives and conclusions reached in this project are: •A litterature search on post dryout heat transfer for pure refrigerants and for refrigerant-oil mixtures was performed and a comprehensive review written (Chapters 9, 10, and 11); •The correct thermodynamic definition of the heat transfer coefficient for evaporation of refrigerant-oil mixtures was presented and then used in the project, i.e. defining the heat transfer coefficient using the local bubble point temperature Tbub of the refrigerant-oil mixture rather than with the saturation temperature of the pure refrigerant Tsat incorrectly used in prior studies (Chapter 3); •A new generalized approach, that is simple to implement, was developed for predicting bubble point temperatures of refrigerant-oil mixtures for miscible oils that can be applied to any refrigerant-oil combination and is accurate over the local oil concentration range from 0-50 wt.% oil range confronted in direct- expansion evaporators with 0-5 wt.% oil in their refrigerant charge (Chapter 4); •A new thermodynamic method for preparation of temperature-enthalpy- vapor quality (T-h-x) curves for refrigerant-oil mixtures for general application was developed and validated against test data (Chapters 5 and 6), including a simple expression for calculating local oil concentrations as a function of vapor quality; •New, accurate thermodynamic methods for preparation of temperature-enthalpy-vapor (T-h-x) curves for the refrigerant blend R-407C and R-407C/oil mixtures were developed for thermal design of evaporators and for the present experimental test, and was validated against measured test data (Chapter 12); •Recommendations were made on how to include oil effects and refrigerant-oil T-h-x curves into evaporator design methods (Chapter 7); •The effects of oil on set-point parameters for control devices were analyzed and some recommendations made (Chapter 8); •An online oil concentration measurement system was perfected using a high accuracy density flowmeter that allowed oil concentrations to be measured accurately and continuously during experiments, such that oil holdup in the heat transfer test sections at high vapor quality could be identified and the correct inlet oil concentrations be measured, and thus utilized to reduce experimental data; a simpler industrial method for applying the measurement system was also developed and presented (Chapter 15); •Experimental results (local heat transfer coefficients, two-phase pressure drops and some two-phase flow patterns) were obtained for R-134a and R-134a/oil mixtures evaporating in plain and microfinned tubes over a wide range of test conditions (Chapters 16 and 17); •Experimental results (local heat transfer coefficients, two-phase pressure drops and some two-phase flow patterns ) were obtained for R-407C and R- 407C/oil mixtures evaporating in plain and microfinned tubes over a wide range of test conditions (Chapters 18 and 19); •The recently proposed flow b