Immunité cellulaireCell-mediated immunity or cellular immunity is an immune response that does not involve antibodies. Rather, cell-mediated immunity is the activation of phagocytes, antigen-specific cytotoxic T-lymphocytes, and the release of various cytokines in response to an antigen. In the late 19th century Hippocratic tradition medicine system, the immune system was imagined into two branches: humoral immunity, for which the protective function of immunization could be found in the humor (cell-free bodily fluid or serum) and cellular immunity, for which the protective function of immunization was associated with cells.
SpectroscopieLa spectroscopie, ou spectrométrie, est l'étude expérimentale du spectre d'un phénomène physique, c'est-à-dire de sa décomposition sur une échelle d'énergie, ou toute autre grandeur se ramenant à une énergie (fréquence, longueur d'onde). Historiquement, ce terme s'appliquait à la décomposition, par exemple par un prisme, de la lumière visible émise (spectrométrie d'émission) ou absorbée (spectrométrie d'absorption) par l'objet à étudier.
Cellule souche neuraleLes cellules souches neurales sont des cellules souches - multipotentes et capables de s'auto-renouveler - dont le potentiel de différenciation est restreint aux types cellulaires neuraux, notamment : Neurone, Astrocyte et Oligodendrocyte. Durant l'embryogenèse, ces cellules souches neurales sont situées dans la zone ventriculaire du tube neural. Elles génèrent l'ensemble des types cellulaires nécessaires au système nerveux central (à l'exception de la microglie), par un processus appelé neurogenèse.
Microscope à contraste de phasethumb|Photographie d'un cellule épithéliale de joue vue par un Microscope à contraste de phase Le microscope à contraste de phase est un microscope qui exploite les changements de phase d'une onde lumineuse traversant un échantillon. Cet instrument fut développé par le physicien hollandais Frederik Zernike dans les années 1930, ce qui lui valut le prix Nobel de physique en 1953. Emilie Bleeker, physicienne reconnue pour le développement d'instruments, est la première à mettre le microscope à contraste de phase en utilisation.
Pile à combustibleUne pile à combustible est un générateur électrochimique produisant une tension électrique grâce à l'oxydation sur une électrode d'un combustible réducteur (par exemple le dihydrogène) couplée à la réduction sur l'autre électrode d'un oxydant, tel que l'oxygène de l'air. Elle est distincte de la pile électrique, qui fonctionne également par réaction d'oxydoréduction, mais qui est constituée d'empilements de métaux. vignette|Pile à combustible de la NASA au méthanol.
Cable theoryClassical cable theory uses mathematical models to calculate the electric current (and accompanying voltage) along passive neurites, particularly the dendrites that receive synaptic inputs at different sites and times. Estimates are made by modeling dendrites and axons as cylinders composed of segments with capacitances and resistances combined in parallel (see Fig. 1). The capacitance of a neuronal fiber comes about because electrostatic forces are acting through the very thin lipid bilayer (see Figure 2).
Voltage clampThe voltage clamp is an experimental method used by electrophysiologists to measure the ion currents through the membranes of excitable cells, such as neurons, while holding the membrane voltage at a set level. A basic voltage clamp will iteratively measure the membrane potential, and then change the membrane potential (voltage) to a desired value by adding the necessary current. This "clamps" the cell membrane at a desired constant voltage, allowing the voltage clamp to record what currents are delivered.
Quantitative phase-contrast microscopyFORCETOC Quantitative phase contrast microscopy or quantitative phase imaging are the collective names for a group of microscopy methods that quantify the phase shift that occurs when light waves pass through a more optically dense object. Translucent objects, like a living human cell, absorb and scatter small amounts of light. This makes translucent objects much easier to observe in ordinary light microscopes. Such objects do, however, induce a phase shift that can be observed using a phase contrast microscope.
Conductivity (electrolytic)Conductivity (or specific conductance) of an electrolyte solution is a measure of its ability to conduct electricity. The SI unit of conductivity is siemens per meter (S/m). Conductivity measurements are used routinely in many industrial and environmental applications as a fast, inexpensive and reliable way of measuring the ionic content in a solution. For example, the measurement of product conductivity is a typical way to monitor and continuously trend the performance of water purification systems.
Discrimination par les prixvignette|Illustration de la discrimination par les prix des articles La discrimination par les prix désigne la modulation par agent des prix de son offre en fonction des caractéristiques connues ou supposées de la demande. Classiquement, on distingue trois types de discriminations par les prix en fonction de l'information dont dispose l'agent discriminateur : Discrimination de premier type, ou discrimination parfaite : le prix est fixé en fonction de la qualité de l'acheteur.
Conductivité thermiqueLa conductivité thermique (ou conductibilité thermique) d'un matériau est une grandeur physique qui caractérise sa capacité à diffuser la chaleur dans les milieux sans déplacement macroscopique de matière. C'est le rapport de l'énergie thermique (quantité de chaleur) transférée par unité de temps (donc homogène à une puissance, en watts) et de surface au gradient de température. Notée λ (anciennement K voire k), la conductivité thermique intervient notamment dans la loi de Fourier.
Laboratoire sur puceUn laboratoire sur puce est un dispositif intégré rassemblant, sur un substrat miniaturisé, une ou plusieurs fonctions de laboratoire. L'analyse du vivant regroupe trois des quatre raisons majeures ayant entraîné le développement de la microfluidique ; elle représente par conséquent une large part des applications. On considère généralement que le premier dispositif microfluidique d'analyse est celui développé par Terry et al. ; ceux-ci réalisent en 1979 un système miniaturisé d'analyse de gaz par chromatographie sur un substrat de silicium.