This study was conducted as part of research line addressing the mechanical response of periodontal ligament (PDL) to tensile-compressive sinusoidal loading The aim of the present project was to determine the effect of three potential sources of variability. (1) specimen geometry, (2) tissue preconditioning and (3) tissue structural degradation over time. For the three conditions, selected mechanical parameters were evaluated and compared
John Christopher Plummer, Laurent Mirko Dejace, Matteo Gregorio Modesto Marascio, Alessandra Apicella
John Christopher Plummer, Matteo Gregorio Modesto Marascio, Alessandra Apicella
John Botsis, Joël Cugnoni, Matteo Galli, Marzio Bergomi