Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
The protein binding of anticancer metallodrugs is regarded as an important part in their mode of action both for delivering the active moiety into the tumor but also being responsible for deactivation and/or unwanted side effects. Characterization of protein binding and release may allow new drugs to be designed which are devoid of protein interactions or capable of binding selectively to protein targets. Herein, we report the comparison of different ionization techniques, i.e. matrix-assisted laser desorption/ionization (MALDI) and nanoelectrospray ionization mass spectrometry (nESI-MS), for the anal. of small protein-Pt anticancer drug interactions. For this purpose, cisplatin, transplatin and oxaliplatin were incubated with the model protein ubiquitin (Ub) at a molar ratio of 2 : 1 (Pt : Ub) followed by MS anal. Cisplatin, transplatin and oxaliplatin formed mainly monoadducts with Ub, but of significantly different compn. As reported earlier, cisplatin forms mainly bifunctional Ub-[Pt(NH3)2] adducts, while with transplatin the most abundant adduct was found to be a monofunctional Ub-[Pt(NH3)2Cl] species. Oxaliplatin formed exclusively bifunctional species of the formula Ub-[Pt(chxn)] (chxn = cyclohexane-1,2-diamine). The applied anal. methods provide comparable results. However, the higher resoln. of the nESI-quadrupole time-of-flight (QToF)-MS allowed unambiguous characterization of a series of mono- and bis-adducts including Ub-[Pt(NH3)2(H2O)] for both cisplatin and transplatin. Applying nESI-ion trap (IT)-MS showed the advantage of higher sensitivity than the ToF instruments, allowing the detection of bisadducts of oxaliplatin after one week of incubation. In contrast to the ESI mass spectra, MALDI showed a higher degree of fragmentation of the Ub-platinum conjugates.
Jan Steggemann, Konstantin Androsov, Anna Mascellani, Joanna Malgorzata Wanczyk, Paul Théodore Gabriel Pablo De Bryas Dexmiers d'Archiac
Christophe Ballif, Edoardo Charbon, Claudio Bruschini, Nicolas Würsch, Luca Massimiliano Antognini, Emanuele Ripiccini, Jad Benserhir, Samira Alexandra Frey