GyratorA gyrator is a passive, linear, lossless, two-port electrical network element proposed in 1948 by Bernard D. H. Tellegen as a hypothetical fifth linear element after the resistor, capacitor, inductor and ideal transformer. Unlike the four conventional elements, the gyrator is non-reciprocal. Gyrators permit network realizations of two-(or-more)-port devices which cannot be realized with just the conventional four elements. In particular, gyrators make possible network realizations of isolators and circulators.
Electrical terminationIn electronics, electrical termination is the practice of ending a transmission line with a device that matches the characteristic impedance of the line. Termination prevents signals from reflecting off the end of the transmission line. Reflections at the ends of unterminated transmission lines cause distortion, which can produce ambiguous digital signal levels and misoperation of digital systems. Reflections in analog signal systems cause such effects as video ghosting, or power loss in radio transmitter transmission lines.
Damping factorIn an audio system, the damping factor gives the ratio of the rated impedance of the loudspeaker (usually assumed to be 8Ω) to the source impedance of the power amplifier. Only the magnitude of the loudspeaker impedance is used, and the power amplifier output impedance is assumed to be totally resistive. In typical solid state and tube amplifiers, the damping factor varies as a function of frequency. In solid state amplifiers, the damping factor usually has a maximum value at low frequencies, and it reduces progressively at higher frequencies.
Onde longitudinaleLongitudinal waves are waves in which the vibration of the medium is parallel to the direction the wave travels and displacement of the medium is in the same (or opposite) direction of the wave propagation. Mechanical longitudinal waves are also called compressional or compression waves, because they produce compression and rarefaction when traveling through a medium, and pressure waves, because they produce increases and decreases in pressure.
ElastanceElectrical elastance is the reciprocal of capacitance. The SI unit of elastance is the inverse farad (F−1). The concept is not widely used by electrical and electronic engineers. The value of capacitors is invariably specified in units of capacitance rather than inverse capacitance. However, it is used in theoretical work in network analysis and has some niche applications at microwave frequencies. The term elastance was coined by Oliver Heaviside through the analogy of a capacitor as a spring.
QuadripôleEn électrocinétique, un quadripôle (ou quadrupôle) est un élément de modèle d'un circuit électrique dans lequel on le considère comme un bloc avec deux connexions d'entrée et deux de sortie. On étudie le transfert des grandeurs électriques, tension et courant, entre ces deux dipôles caractérisés par une impédance, en fonction du temps. Quand l'étude du quadripôle concerne un signal électrique, la grandeur en entrée et en sortie peut être différente (tension, courant).
P waveA P wave (primary wave or pressure wave) is one of the two main types of elastic body waves, called seismic waves in seismology. P waves travel faster than other seismic waves and hence are the first signal from an earthquake to arrive at any affected location or at a seismograph. P waves may be transmitted through gases, liquids, or solids. The name P wave can stand for either pressure wave (as it is formed from alternating compressions and rarefactions) or primary wave (as it has high velocity and is therefore the first wave to be recorded by a seismograph).
Overhead power lineAn overhead power line is a structure used in electric power transmission and distribution to transmit electrical energy across long distances. It consists of one or more uninsulated electrical cables (commonly multiples of three for three-phase power) suspended by towers or poles. Since most of the insulation is provided by the surrounding air, overhead power lines are generally the least costly method of power transmission for large quantities of electric energy.
Pylône électriqueUn pylône électrique est un support vertical portant les conducteurs d'une ligne à haute tension. Le plus souvent métallique, il est conçu pour supporter un ou plusieurs câbles aériens et résister aux aléas météorologiques et sismiques (foudre y compris), aux vibrations des câbles et/ou du pylône, et ses fondations (fichées ou en dalle) sont adaptées au type de substrat (des sols rocheux à pulvérulents en passant par les substrats argileux éventuellement vulnérable au phénomène de retrait-gonflement des argiles).
Reflections of signals on conducting linesA signal travelling along an electrical transmission line will be partly, or wholly, reflected back in the opposite direction when the travelling signal encounters a discontinuity in the characteristic impedance of the line, or if the far end of the line is not terminated in its characteristic impedance. This can happen, for instance, if two lengths of dissimilar transmission lines are joined. This article is about signal reflections on electrically conducting lines.
Gestionnaire de réseau de transportDans l'Union européenne, un gestionnaire de réseau de transport (GRT) est une entreprise chargée de la gestion de tout ou partie d'un réseau de transport d'énergie (électricité ou gaz). Le réseau de transport est complété par le réseau de distribution, auquel sont reliés la plupart des consommateurs ; seuls quelques gros consommateurs (dits « électro-intensifs » ou plus rarement « gaz-intensifs ») sont directement connectés au réseau de transport.
S waveNOTOC In seismology and other areas involving elastic waves, S waves, secondary waves, or shear waves (sometimes called elastic S waves) are a type of elastic wave and are one of the two main types of elastic body waves, so named because they move through the body of an object, unlike surface waves. S waves are transverse waves, meaning that the direction of particle movement of a S wave is perpendicular to the direction of wave propagation, and the main restoring force comes from shear stress.