DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The present work shows the attenuation factors of an imperfect Faraday cage with respect to stiff front time Impulse waves. The aim of this work is to simulate the comportment of sensitive measuring electronic devices boxes against inpulse phenomena. For testing the cage perfomances high precision data acquisition and processing is needed. An original method permitting such measurements in a highly electromagneticaly perturbed environment is described. Result of measurements on a real scale for both the magnetic and electric field attenuation factor are given.