DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Curved channels in the form of bends are encountered in many industrial two-phase flow applications, such as U-bends in air-conditioning and refrigeration evaporators and condensers. For engineering design purposes, the evaluation of the pressure loss in two-phase flows is necessary. Basically, for the same flow conditions the pressure loss is higher in a U-bend than in a straight pipe with an equal cross-flow section and mean length. Moreover, the curved tube causes a perturbation that propagates up- and downstream of the U-bend itself Many studies have been made on two-phase flows in bent tubes, but none have yet focused on the axial evolution of the pressure gradients before and after the U-bend or on the peripheral pressure differences that may be created. Therefore, this study reports new data obtained for R-134a at saturation temperatures ranging from 3 degrees C to 5 degrees C (37 degrees F to 41 degrees F), flowing at mass velocities ranging from 155 to 533 kg.s(-1).m(-2) (114.10(3) to 393-10(3) ft(-2)) through a horizontal U-bend tube with internal tube and bend centerline diameters of 13.4 mm (0.52 in.) and 66.1 mm (2.6 in.), respectively, over a wide range of vapor qualities. The experimental results show that the differences between the peripheral inner and outer pressures up- and downstream of the bend are negligible, even very close to the bend (at 4 internal diameters). The frictional pressure gradients in the U-bend were found experimentally to be about two times that in a straight pipe. Close to the bend, up- and downstream, the pressure gradients are highly affected. For lower and medium mass velocities the perturbation caused by the U-bend does not propagate further than 6 internal diameters upstream from the bend. For the higher mass velocity, that perturbation seems to propagate further. Downstream of the U-bend the perturbed length extends over 100 internal diameters.
Anna Fontcuberta i Morral, Alok Rudra, Santhanu Panikar Ramanandan, Joel René Sapera