Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Many future fusion devices will rely heavily, if not solely, on electron cyclotron (EC) heating subsystems to provide bulk heating, instability control (neoclassical tearing mode (NTM) stabilization), and thermal instability control. Efficient use of the installed heating power (gyrotrons) requires low-loss transmission of the power over 100s of meters since the mm-wave sources need to be installed where the stray magnetic field has a small amplitude. Transmission lines are used to propagate the mm-wave power over this long distance. Quasi-optical techniques (mirrors) are used at W7X and are planned for DTT, for example. Guided components are installed at DIII-D, TCV and elsewhere and are planned at JT60SA and ITER. High power test facilities exist to evaluate the power transmission of assemblies of guided components (transmission lines). The European test facility FALCON was setup by Switzerland and Fusion for Energy (F4E) in Lausanne Switzerland at the Swiss Plasma Center (SPC) in the Ecole Polytechnique Federale de Lausanne (EPFL). Operations are funded through a framework contract with F4E. SPC operates the facility. Two ITER-class 170GHz gyrotrons are housed within the facility and used to evaluate the thermal behaviour of components provided by various ITER partners. Loss measurements are presented for miter bends and waveguides of several materials at two different diameters. The results are used to model the expected losses in the ITER ex-vessel waveguides (EW) of all five EC launchers.Many future fusion devices will rely heavily, if not solely, on electron cyclotron (EC) heating subsystems to provide bulk heating, instability control (neoclassical tearing mode (NTM) stabilization), and thermal instability control. Efficient use of the installed heating power (gyrotrons) requires low-loss transmission of the power over 100s of meters since the mm-wave sources need to be installed where the stray magnetic field has a small amplitude. Transmission lines are used to propagate the mm-wave power over this long distance. Quasi-optical techniques (mirrors) are used at W7X and are planned for DTT, for example. Guided components are installed at DIII-D, TCV and elsewhere and are planned at JT60SA and ITER. High power test facilities exist to evaluate the power transmission of assemblies of guided components (transmission lines). The European test facility FALCON was setup by Switzerland and Fusion for Energy (F4E) in Lausanne Switzerland at the Swiss Plasma Center (SPC) in the Ecole Polytechnique Federale de Lausanne (EPFL). Operations are funded through a framework contract with F4E. SPC operates the facility. Two ITER-class 170GHz gyrotrons are housed within the facility and used to evaluate the thermal behaviour of components provided by various ITER partners. Loss measurements are presented for miter bends and waveguides of several materials at two different diameters. The results are used to model the expected losses in the ITER ex-vessel wav
Olivier Sauter, Stefano Coda, Alexander Karpushov, Benoît Labit, Antoine Pierre Emmanuel Alexis Merle, Olivier Claude Martin Février, Simon Van Mulders, Filippo Bagnato, Alessandro Pau, Matteo Vallar, Cassandre Ekta Contré, Stefano Marchioni, Oleg Krutkin, Reinart Andreas J. Coosemans
Federico Alberto Alfredo Felici, Alessandro Pau
Olivier Sauter, Stefano Coda, Justin Richard Ball, Filippo Bagnato, Matteo Vallar