DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Within the EFDA technology program, CRPP designed and prepared a short length of full size Nb3Sn developmental conductor to be tested in the SULTAN test facility. Nb3Sn strand with a higher specification and low Cu:non-Cu ratio was supplied by Outokumpu. Half of the produced wire length has been Cr-plated half was left bare. Subsequently, two Ti-jacketed cable-in-conduit conductors based on a braid as the first stage, have been manufactured by VNIIKP. After reaction heat treatment, the annular space of the conductor piece without coating was filled with solder. The measurements indicate a higher performance of the solder-filled conductor suggesting that an adequate mechanical support of the strands in the cable may avoid transverse load degradation.