DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
SO2 is removed from mineral acids, e.g., HCl, in an exchange column consisting of an absorption section with 5-10 plates, a cooling section, and a stripping section with 10-15 plates at the bottom. The choice of stripping gas is detd. by the subsequent treatment of the SO2. Thus, when a 50:50 gaseous mixt. of HCl and SO2 is fed into the absorption section (70-85 Deg) at 120 L/h with air (stripping gas) fed at 40 L/h into the stripping section (15 Deg) and water at a rate to give a 30 or 20% concn. of HCl, the purified acid contains SO2