DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
A micro pump was integrated into a scanning force microscope probe for circulating liquid through its hollow cantilever and tip. The interior cross section of the cantilever was 2.25 mu m x 3.75 mu m. All fluidic parts were made of SiO2, while the tip apex was made of Si3N4. The key fabrication techniques were silicon wafer bonding and wet-oxidation. The pumping mechanism was relying on the enhanced evaporation at an enlarged water/air interface at the exit of the microchannel. Capillary forces continuously wetted this interfacial area, thus drawing the liquid through the system. At room temperature, a pump rate of 11 pl s(-1) was experimentally evaluated. The observed temperature dependence of the pump rate could be qualitatively understood by a plain model calculation. (C) 2007 Elsevier B.V. All rights reserved.