DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The coupling of shear walls using reinforced concrete coupling beams in high-rise buildings sub-jected to lateral loads is studied. The axial restraint phenomena is investigated using different nonlinear finite element models based on a reinforced concrete coupling beam cross-section. As shown by the models, axial restraint provided by other structural elements such as shear walls and floor diaphragms has to be taken into account because it has a positive impact on the be-havior of the whole coupled wall system. This study also aims to provide clear design guidelines for engineers, and it is within this context that a case study is presented. This study proposes a simplified and efficient approach to incorporate axial restraint in the design of coupled wall systems.