DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The reactive liquid infiltration (RLI) technique, applied to-the MgB2 material, has allowed us to obtain either bulk or wire samples of good transport properties. The evaluation of the voltage-current characteristics, V-I-n, for typical samples, measured by transport at temperatures between 4.2 and 30 K, is presented. The behaviour of the n exponent is discussed in terms of a simple model and the differences between bulk and wire samples are outlined. (C) 2003 Elsevier B.V. All rights reserved.