DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Single plate shear tab connections are a simple means to connect beams to their supporting members. The tab is fillet-welded to the supporting column in the fabrication shop, and then field bolted to the beam web on the construction site. Sit-uations may arise on site in which the bolt holes do not align. Instead of reaming holes or refabricating the connection, a cost efficient alternative is to use a weld-retrofit connection between the beam web and the shear tab. The AISC recommends that this retrofit approach not be taken due to concerns with the rotational ductility of the connection; however, no test-based performance evaluation was available for the weld-retrofit connection. The intent of the paper is to summarize the laboratory phase of a research project in which various weld-retrofit schemes of shear tab con-nections were evaluated. The connection performance is compared with nominally identical bolted shear tab connections.
Dimitrios Lignos, Andronikos Skiadopoulos
Dimitrios Lignos, Andronikos Skiadopoulos