DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Liquid cooling in thermal management systems has been implemented mostly through the use of thermal interface materials, which introduce in in-series parasitic thermal resistances and reduced thermal performance. To achieve the full potential of liquid cooling, cooling structures should be fabricated directly in-chip, enabling effective heat transfer near the junction. In this work, we investigate an integrated cooling module encompassing enhanced fin structures (diamond-shaped and square pin fins) with an impinging jet manifold. Low thermal resistance of 0.1 cm2.K/W was achieved, while consuming a record low pumping power of 40μ W/mm2 using 25 μm channel width. Our approach was compared with bulky traditional fan cooling and no cooling cases, and resulted in 6.6x and 62 x reduction in thermal resistance, respectively. The cooling structure was directly fabricated at the back side of a GaN power IC which resulted in a thermal resistance of 1 K/W at 10 mW pumping power, 6.6 K/W thermal resistance was realized using fan cooling. Furthermore, 37 % increase in dynamic on-resistance (Ron) was reported at 10 W power dissipation using fan cooling, which was reduced to 12 % when using our approach at 15 W power dissipation.