Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Background Long acquisition times and motion sensitivity limit T-2 mapping in the abdomen. Accelerated mapping at 3 T may allow for quantitative assessment of diffuse pancreatic disease in patients during free-breathing. Purpose To test the feasibility of respiratory-triggered quantitative T-2 analysis in the pancreas and correlate T-2-values with age, body mass index, pancreatic location, main pancreatic duct dilatation, and underlying pathology. Study Type Retrospective single-center pilot study. Population Eighty-eight adults. Field Strength/Sequence Ten-fold accelerated multiecho-spin-echo 3 T MRI sequence to quantify T-2 at 3 T. Assessment Two radiologists independently delineated three regions of interest inside the pancreatic head, body, and tail for each acquisition. Means and standard deviations for T-2 values in these regions were determined. T-2-value variation with demographic data, intraparenchymal location, pancreatic duct dilation, and underlying pancreatic disease was assessed. Statistical Tests Interreader reliability was determined by calculating the interclass coefficient (ICCs). T-2 values were compared for different pancreatic locations by analysis of variance (ANOVA). Interpatient associations between T-2 values and demographical, clinical, and radiological data were calculated (ANOVA). Results The accelerated T-2 mapping sequence was successfully performed in all participants (mean acquisition time, 2:48 +/- 0:43 min). Low T-2 value variability was observed across all patients (intersubject) (head: 60.2 +/- 8.3 msec, body: 63.9 +/- 11.5 msec, tail: 66.8 +/- 16.4 msec). Interreader agreement was good (ICC, 0.82, 95% confidence interval: 0.77-0.86). T-2-values differed significantly depending on age (P < 0.001), location (P < 0.001), main pancreatic duct dilatation (P < 0.001), and diffuse pancreatic disease (P < 0.03). Data Conclusion The feasibility of accelerated T-2 mapping at 3 T in moving abdominal organs was demonstrated in the pancreas, since T-2 values were stable and reproducible. In the pancreatic parenchyma, T-2-values were significantly dependent on demographic and clinical parameters. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:410-416.
Dimitri Nestor Alice Van De Ville, Nawal Noëlle Kinany
Jan Steggemann, Konstantin Androsov, Anna Mascellani