DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This paper deals with an efficient implementation of an H multi-variable controller on the three degrees of freedom (DOF) parallel robot namely the Delta robot'. The H controller is designed by the mixed sensitivity approach in which the sensitivity function matrix S and the complementary sensitivity function matrix T are taken into account. For this purpose, a nonlinear analytical dynamic state model is developed and a tangent linearization procedure is used to obtain a multi-variable linear model around a functional point. Real-time experiments were performed to compare the centralized H controller with a classical decentralized Proportional Integral Derivative (PID) controller. Experimental tracking results show that the performances of the PID compared to those of the H decrease when the movement dynamic is increased. At high dynamic (12Ge), it is shown that the maximum tracking error and the error around the stop positions of the H are, respectively, 80 and 60% of the PID. The experiments of the load variation have proven that the H is more robust than the PID. The steady-state root mean square error of the H is less than 60% of the one obtained using the PID controller.