Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
We present a parametrised Preisach-type model that describes the hysteresis exhibited by the high temperature superconductors (HTSC); hysteresis is the main cause for losses in the subcritical domain. The parametrised model, in combination with electrical measurements, is independent of geometry, number of filaments and other physical measures, and is identified by a novel method that uses electrical lock-in (loss) measurement technique, which greatly enhances the signal to noise ratio. Identification results from measurements on Bi-2223 multi-filamentary tapes are presented. We have further derived exact models for the hysteretic losses in strip and elliptic geometry strips, where the energy losses were calculated by Norris. The paper contains analysis of the Preisach Model, of its losses and of the suggested parametrisation.