DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
An unbalanced DC-link voltage regulation strategy is proposed for a three-level voltage source inverter used in the rotor cascade of a double-fed asynchronous motor-generator. The major problem in determining the presence of the unbalanced component is investigated and a solution is proposed using an adaptable filter. This latter is only of a low order and is designed to ensure easy implementation into a (DSP). The regulator is based on the injection of a second order harmonic and its design is presented as well as an investigation of the critical point for correct action of the regulator. Real measurements performed on a low-power test bench after implementation into a DSP validate the accuracy and quality of the filter as well as the control strategy proposed.
Drazen Dujic, Andrea Cervone, Tianyu Wei