DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The early time high altitude electromagnetic pulse conducted environment calculation is revisited by using the transmission line (TL) theory and including high-frequency corrections that were not present in the earlier studies. Waveform salient parameters, such as the current peak, rise time, and pulsewidth, are studied as a function of a number of parameters involved in the calculation. The obtained cumulative distribution functions of the parameter probabilities are discussed and compared with the existing standards for the HEMP protection. The high-frequency correction to the TL model results in a decrease of the current amplitudes of 15–20%. For the highest currents, rise times in the range of 25 ns are obtained. A less significant impact was found in the calculation of the pulsewidth, which was increased to about 150 ns.