DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
The toroidal Field Conductor Insert (TFCI) coil was tested at 46 kA in the 13 T background magnetic field generated by the Central Solenoid Model Coil. The single layer TFCI coil uses a Nb3Sn cable-in-conduit conductor in a Titanium jacket. The object of this work is to verify the data self-consistency, and to apply a thermal, hydraulic and electrical simulation to derive the strand performance in the cable. We present the results of the analysis in support of the interpretation of a subset of current sharing temperature measurements. After estimation of the n-value in the voltage-current equation, we perform the simulations using the total longitudinal strain as the only fitting parameter; the resulting value is much larger than the value expected from simple thermal contraction considerations.