DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Glass-fiber-reinforced polymer (GFRP) cell-core sandwiches are composed of outer GFRP face sheets, a foam core, and a grid of GFRP webs integrated into the core to reinforce the shear load capacity. One of the critical failure modes of cell-core sandwich structures is shear wrinkling, a local buckling failure in the sandwich webs because of shear loading. The shear wrinkling behavior of GFRP laminates with different laminate sequences, stabilized by a polyurethane foam core, was experimentally and numerically investigated. Shear wrinkling was simulated by a biaxial compression-tension setup. The results show that an increasing transverse tension load significantly decreases the wrinkling load. The decreasing effect of tension is explained by the lateral contraction because of Poisson's effect, which causes an increase in the initial imperfections and subsequent accelerated bending. DOI: 10.1061/(ASCE)CC.1943-5614.0000212. (C) 2011 American Society of Civil Engineers.
Katrin Beyer, Francesco Vanin, Ivana Bozulic