DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
In the frame of the European project UNIFLEX-PM, two AC/AC converter topologies hove been studied and implemented. Both converters, rated for 25 kVA, are isolated by a medium-frequency power transformer. The first topology is based on a dual active bridge containing two additional voltage source inverters for the connection of both DC links to the interfaced grids. The second topology is based on a cycloconverter for the connection of the secondary side of the transformer to the grid without a DC link capacitor Both topologies hove an identical primary side so the efficiency study is focussed on the chain link from one DC link to a 25 kW output load. Experimental efficiencies are compared to theoretical expectations. Due to soft-switching operation hi the dual active-bridge, the cycloconverter based solution shows a lower efficiency than in the symmetrical topology.
Drazen Dujic, Andrea Cervone, Tianyu Wei
Drazen Dujic, Andrea Cervone, Tianyu Wei