DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Glass fiber-reinforced (GFRP) cell-core sandwich structures are increasingly used in bridge deck and roof construction. GFRP cell-core sandwiches are composed of the outer GFRP face sheets, a foam core and a grid of GFRP webs integrated into the core in order to reinforce the shear load capacity. One of the critical failure modes is shear wrinkling, a local buckling failure in the sandwich webs due to shear loading. Shear wrinkling is a biaxial compression-tension wrinkling problem and, for this reason, the numerous results of pure compressive wrinkling research are not necessarily applicable. The details and results of in-plane biaxial compression-tension wrinkling experiments on GFRP sandwich laminates, stabilized by a polyurethane foam core, are presented. It is shown that an increasing transverse tension load significantly decreases the wrinkling load. These results are confirmed by finite element calculations.