DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Many popular micropumps implement moving parts that presents serious drawbacks. This is one of the reasons for the growing interest in valveless micropumps. Pumps exploiting AC electric fields are investigated here. Theoretical results are recalled and the behaviour of fabricated glass and PDMS prototypes is presented and compared to simulations. Recirculation of liquid in the pumping channel is explained by geometrical reasons.
Jean-Jacques Simond, Basile Kawkabani