DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
This paper presents a new concept for a lightweight hybrid- FRP bridge deck. The sandwich construction consists of three layers: a fiber-reinforced polymer composite (FRP) sheet with T-upstands for the tensile skin, lightweight concrete (LC) for the core and a thin layer of ultra high performance reinforced concrete (UHPFRC) as a compression skin. Mechanical tests on eight hybrid beams were performed with two types of LC and two types of FRP/LC interface: unbonded (only mechanical interlocking of LC between T- upstands) and bonded with an epoxy adhesive. The ultimate loads of the beams increased by 104% on average due to bonding. However, the beam failure mode changed from ductile to brittle. The beams using a LC of 44% higher density exhibited an 81% increase in the ultimate load. The manufacturing of the beams proved to be economic in that epoxy and concrete layers were rapidly and easily applied wet-in-wet without intermediate curing times. The experimental results showed positive results regarding the feasibility of the suggested hybrid bridge deck. [All rights reserved Elsevier]
Marie Estelle Solange Violay, Gabriel Gérard Dominique Meyer, Francesco Lazari
Eugen Brühwiler, Alain Nussbaumer, Jian Zhan