DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
We propose and experimentally demonstrate the possibility to use a pump signal based on bipolar pulse sequences using single-sideband suppressed-carrier (SSB-SC) modulation in Brillouin optical time-domain analysis (BOTDA) sensors. The SSB-SC modulated pump makes a sequential use of the Brillouin gain and loss spectra, increasing the intensity contrast of the measurements. The method is demonstrated using bipolar Golay codes along a 50 km sensing fiber and 2 m spatial resolution. Results indicate that the use of bipolar sequences provides a higher SNR enhancement and stronger robustness to pump depletion in comparison to BOTDA systems employing conventional unipolar sequences.