DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Experimental data characterizing indoor electric and magnetic fields radiated by power line communication (PLC) systems and used for the calculation of a local transfer function (coupling factor) are presented. It is shown that the indirect determination of electric field using magnetic field measurements and assuming a plane wave approximation may result in an underestimation of the electric field. Additionally, it is shown that the radiated field magnitudes vary significantly as a function of the position of the observation point and of the network load. A first evaluation of the indoor electromagnetic field radiated by PLC systems using NEC2 is presented and compared with experimental data.