DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
After 10,000 h solid oxide fuel cell (SOFC) stack operation, the Cr-poisoning situation in (La0.6Sr0.4) (Co0.2Fe0.8)O-3 (LSCF)-based cathode material is depicted in this work. Systematic Cr profiling by energy-dispersive X-ray spectroscopy (EDS), from post-operation samples taken at different locations within the air flow field, reveals Cr accumulation in electrochemically active cathode regions, although the major amount of Cr is trapped in inactive surface-proximal cathode regions; the 20 m LSCF current collector does not fully impede the Cr access to the functional cathode.