Ask any question about EPFL courses, lectures, exercises, research, news, etc. or try the example questions below.
DISCLAIMER: The Graph Chatbot is not programmed to provide explicit or categorical answers to your questions. Rather, it transforms your questions into API requests that are distributed across the various IT services officially administered by EPFL. Its purpose is solely to collect and recommend relevant references to content that you can explore to help you answer your questions.
Operating the cooling system of a methanation reactor using an open-loop two-phase thermosiphon with evaporating water as the cooling liquid is an effective way to ensure safe operation as it does not rely on a recirculating pump. The aim of the reactor design is to co-generate methane and steam, the latter to be used in a solid-oxide electrolyzer to produce H2 to be injected in the reactor. The passive operation was analyzed to ensure a similar level of stability in the steam production compared to the active operation (i.e., with a pump). A total of 98% of the measured steam produced in passive cooling were within ±9.82% of the individual means, comparing well to ±9.5% for the active cooling operation.
John Richard Thome, Filippo Cataldo
Michael Lehning, Bettina Schaefli, Wolf Hendrik Huwald, Adrien Michel, Tristan Jonas Brauchli
John Richard Thome, Rémi Revellin