The fourth China TF conductor sample (TFCN4) for Phase II, the left leg of the fifth China TF conductor sample (TFCN5) for Phase III, as well as the right leg of the TFCN5 conductor for Phase IV, were made of the WST strands, cabled by Baosheng, jacketed a ...
IEEE Institute of Electrical and Electronics Engineers2014
The performance of two Nb3Sn conductors for the ITER central solenoids was tested. The current sharing temperatures (T-cs) were measured over 17 050 electromagnetic cycles, including four thermal cycles between 4.2 K and room temperature. T-cs declined alm ...
IEEE Institute of Electrical and Electronics Engineers2013
In the assumption that DEMO will be an inductively driven tokamak, the number of load cycles will be in the range of several hundred thousands. The requirements for a new generation of Nb3Sn based high current conductors for DEMO are drafted starting from ...
The test campaigns of the ITER conductors in the SULTAN test facility re-started in December 2011 after three months break. The main focus of the activities is about the qualification tests of the Central Solenoid (CS) conductors, with three different samp ...